メインコンテンツへスキップ

Voltage Asymmetry calculation - MFR300 - MFR13 - ナレッジベース / MFR300 - Power Management

Voltage Asymmetry calculation - MFR300 - MFR13

作成者一覧


MFR13

  • The MFR13 calculates the asymmetry as the maximum deviation of each delta voltage from the average.

  • In Principle, it’s the ANSI standard, but

    • ANSI: monitor MAX / Average in [%]

    • MFR13: monitor MAX-Average in [V]


MFR300

The MFR300 calculates the asymmetry from the negative sequence in relation to the nominal voltage

The formula of the negative sequence is:

volt-asymm.png

The monitoring would be for |G| / nominal voltage